AWA MODULA 250


The AWA MODULA 250 system produces up to 2500 litres per day of very high quality water.

Alongside water production for a simple system, the AWA MODULA 250 system can also be configured to integrate and complement existing HVAC (Heating, Ventilation, and Air Conditioning) systems by simultaneously producing:

  • Primary Cool Air at 22°C and 40% R.H. (8,000 m3/hour)
  • Cooling of water to 7°C
  • Heating of external water source to 50°C up to 2000 Litres/Hour

The utilisation of the HVAC (cool air, hot water, cold water) energy produced during water production can provide substantial energy cost savings which can totally offsets the cost of water production.

The AWA MODULA 250 system can be easily installed in private homes, hotels, resorts, residential buildings, hospitals, farms, camps, communities, greenhouses, hydroponics and irrigation.

atmos blue

  • 250-W-X
  • CHARACTERISTICS AWA MODULA 250-W-X
    Nominal water production 2500 litres/day
    Installed electrical power 60 kW (54 kW + 10%)
    Nominal environment conditions 30° C & 70% R.H.
    Energy consumption 0.28 kWh/litre
    Cooling circuit coolant  R134a
    Sound pressure level 75 dBA (at a distance of 10 m)
    Size (W x D x H) 4950 x 2230 x 2470 mm
    Weight 5000 kg
    Operating range from 5° C / 90% R.H. to 50° C/10% R.H.
    X (Model) Power supply
    S version 400 V + 10% / 3Ph + Ground / 50 Hz
    A version 460 V+ 10% / 3Ph + Ground / 60 Hz
    L version 220 V + 10% / 3Ph + Ground / 60 Hz
  • 250-HWA-X
  • CHARACTERISTICS AWA MODULA 250-HWA-X
    Nominal water production 2500 litres/day
    Installed electrical power 60 kW (54 kW + 10%)
    Nominal environment conditions 30° C & 70% R.H.
    Energy consumption 0.28 kWh/litre
    Cooling circuit coolant  R134a
    Sound pressure level 75 dBA (at a distance of 10 m)
    Size (W x D x H) 4950 x 2230 x 2470 mm
    Weight 5500 kg
    Operating range from 5° C / 90% R.H. to 50° C/10% R.H.
       
    Available heating thermal power (Water) 120 kW – 2000 litres/hour 50° C
    Available cooling thermal power (Air) 100 kW – 8000 m3/hour at 24° C 40% R.H.
    X (Model) Power supply
    S version 400 V + 10% / 3Ph + Ground / 50 Hz
    A version 460 V+ 10% / 3Ph + Ground / 60 Hz
    L version 220 V + 10% / 3Ph + Ground / 60 Hz
  • 250-HWAC-X
  • CHARACTERISTICS AWA MODULA 250-HWAC-X
    Nominal water production 2500 litres/day
    Installed electrical power 60 kW (54 kW ± 10%)
    Nominal environment conditions 30° C & 70% R.H.
    Energy consumption 0.28 kWh/litre
    Cooling circuit coolant R134a
    Sound pressure level 75 dBA (at a distance of 10 m)
    Size (W x D x H) 4950 x 2230 x 2470 mm
    Weight 5800 kg
    Operating range from 5° C / 90% R.H. to 50° C/10% R.H.
       
    Available heating thermal power (Water) 120 kW – 2000 litres/hour 50° C
    Available cooling thermal power (Air) 100 kW – 8000 m3/hour at 24° C 40% R.H.
    Available cooling thermal power (Water) From 25 to 100 kW*
    X (Model) Power supply
    S version 400 V + 10% / 3Ph + Ground / 50 Hz
    A version 460 V+ 10% / 3Ph + Ground / 60 Hz
    L version 220 V + 10% / 3Ph + Ground / 60 Hz