AWA MODULA 500


The AWA MODULA 500 system produces up to 5000 litres per day of very high quality water.

Alongside water production for a simple system, the AWA MODULA 500 system can also be configured to integrate and complement existing HVAC (Heating, Ventilation, and Air Conditioning) systems by simultaneously producing:

  • Primary Cool Air at 22°C and 40% R.H. (16,000 m3/hour)
  • Cooling of water to 7°C
  • Heating of external water source to 50°C up to 4000 Litres/Hour

The utilisation of the HVAC (cool air, hot water, cold water) energy produced during water production can provide substantial energy cost savings which can totally offsets the cost of water production.

The AWA MODULA 500 system can be easily installed in private homes, hotels, resorts, residential buildings, hospitals, farms, camps, communities, greenhouses, hydroponics and irrigation.

AWA-500-NEW_atmos_4

  • 500-W-X
  • CHARACTERISTICS AWA MODULA 500-W-X
    Nominal water production 5000 litres/day
    Installed electrical power 120 kW (110 kW ± 10%)
    Nominal environment conditions 30° C & 70% R.H.
    Energy consumption 0.28 kWh/litre
    Cooling circuit coolant Environment friendly – R134a
    Sound pressure level 78 dBA (at a distance of 10 m)
    Size (W x D x H) 7300 x 2230 x 2470 mm
    Weight 8500 kg
    Operating range from 5° C / 90% R.H. to 50° C/10% R.H.
    X (Model) Power supply
    S version 400 V + 10% / 3Ph + Ground / 50 Hz
    A version 460 V+ 10% / 3Ph + Ground / 60 Hz
    L version 220 V + 10% / 3Ph + Ground / 60 Hz
  • 500-HWA-X
  • CHARACTERISTICS AWA MODULA 500-HWA-X
    Nominal water production 5000 litres/day
    Installed electrical power 120 kW (110 kW ± 10%)
    Nominal environment conditions 30° C & 70% R.H.
    Energy consumption 0.28 kWh/litre
    Cooling circuit coolant Environment friendly – R134a
    Sound pressure level 78 dBA (at a distance of 10 m)
    Size (W x D x H) 7300 x 2230 x 2470 mm
    Weight 8500 kg
    Operating range from 5° C / 90% R.H. to 50° C/10% R.H.
       
    Available heating thermal power (Water) 240 kW – 4000 litres/hour 50° C
    Available cooling thermal power (Air) 200 kW – 16000 m3/hour at 24° C 40% R.H.
    X (Model) Power supply
    S version 400 V + 10% / 3Ph + Ground / 50 Hz
    A version 460 V+ 10% / 3Ph + Ground / 60 Hz
    L version 220 V + 10% / 3Ph + Ground / 60 Hz
  • 500-HWAC-X
  • CHARACTERISTICS AWA MODULA 500-HWAC-X
    Nominal water production 5000 litres/day
    Installed electrical power 120 kW (110 kW ± 10%)
    Nominal environment conditions 30° C & 70% R.H.
    Energy consumption 0.28 kWh/litre
    Cooling circuit coolant Environment friendly – R134a
    Sound pressure level 78 dBA (at a distance of 10 m)
    Size (W x D x H) 7300 x 2230 x 2470 mm
    Weight 8500 kg
    Operating range from 5° C / 90% R.H. to 50° C/10% R.H.
       
    Available heating thermal power (Water) 240 kW – 4000 litres/hour 50° C
    Available cooling thermal power (Air) 200 kW – 16000 m3/hour at 24° C 40% R.H.
    Available cooling thermal power (Water) From 25 to 200 kW*
    X (Model) Power supply
    S version 400 V + 10% / 3Ph + Ground / 50 Hz
    A version 460 V+ 10% / 3Ph + Ground / 60 Hz
    L version 220 V + 10% / 3Ph + Ground / 60 Hz