Water production of 10000 l/day. Modula systems are built on a standard industrial modular base, they are substantially easier to manufacture and are more energy efficient. The basic Modula system will produce 10,000 litres of water per day. MODULA strategy permits system planning integrated in a building with a series of UTA decentralized and connected with ATWG for the water and air-conditioning generator. Engineered for simple installation. All with same energy consumption compare to the actual Air conditioning System. Low energy, low cost. Fast return.
CHARACTERISTICS | AWA MODULA 1000-W-X | |
---|---|---|
Nominal water production | 10000 litres/day | |
Installed electrical power | 220 kW (200 kW ± 10%) | |
Nominal environment conditions | 30° C & 70% R.H. | |
Energy consumption | 0.28 kWh/litre | |
Cooling circuit coolant | Environment friendly – R134a | |
Sound pressure level | 80 dBA (at a distance of 10 m) | |
Size (W x D x H) | 13150 x 2230 x 2470 mm | |
Weight | 16300 kg | |
Operating range | from 5° C / 90% R.H. to 50° C/10% R.H. |
X (Model) | Power supply | |
---|---|---|
S version | 400 V + 10% / 3Ph + Ground / 50 Hz | |
A version | 460 V+ 10% / 3Ph + Ground / 60 Hz | |
L version | 220 V + 10% / 3Ph + Ground / 60 Hz |
CHARACTERISTICS | AWA MODULA 1000-HWA-X | |
---|---|---|
Nominal water production | 10000 litres/day | |
Installed electrical power | 220 kW (200 kW ± 10%) | |
Nominal environment conditions | 30° C & 70% R.H. | |
Energy consumption | 0.28 kWh/litre | |
Cooling circuit coolant | Environment friendly – R134a | |
Sound pressure level | 80 dBA (at a distance of 10 m) | |
Size (W x D x H) | 13150 x 2230 x 2470 mm | |
Weight | 16300 kg | |
Operating range | from 5° C / 90% R.H. to 50° C/10% R.H. | |
Available heating thermal power (Water) | 480 kW – 8000 litres/hour 50° C | |
Available cooling thermal power (Air) | 400 kW – 32000 m3/hour at 24° C 40% R.H. | |
X (Model) | Power supply | |
---|---|---|
S version | 400 V + 10% / 3Ph + Ground / 50 Hz | |
A version | 460 V+ 10% / 3Ph + Ground / 60 Hz | |
L version | 220 V + 10% / 3Ph + Ground / 60 Hz |
CHARACTERISTICS | AWA MODULA 1000-HWAC-X | |
---|---|---|
Nominal water production | 10000 litres/day | |
Installed electrical power | 220 kW (200 kW ± 10%) | |
Nominal environment conditions | 30° C & 70% R.H. | |
Energy consumption | 0.28 kWh/litre | |
Cooling circuit coolant | Environment friendly – R134a | |
Sound pressure level | 80 dBA (at a distance of 10 m) | |
Size (W x D x H) | 13150 x 2230 x 2470 mm | |
Weight | 16300 kg | |
Operating range | from 5° C / 90% R.H. to 50° C/10% R.H. | |
Available heating thermal power (Water) | 480 kW – 8000 litres/hour 50° C | |
Available cooling thermal power (Air) | 400 kW – 32000 m3/hour at 24° C 40% R.H. | |
Available cooling thermal power (Water) | From 25 to 400 kW* |
X (Model) | Power supply | |
---|---|---|
S version | 400 V + 10% / 3Ph + Ground / 50 Hz | |
A version | 460 V+ 10% / 3Ph + Ground / 60 Hz | |